0

My Cart

0
Subtotal: $0

No products in the cart.

No products in the cart.

0

My Cart

0
Subtotal: $0

No products in the cart.

No products in the cart.

What foundation or footing is required beneath a glass pool fence?

To safely support the immense weight and wind leverage of a glass pool fence, you must have a completely rigid, unyielding structural foundation. A standard 12mm frameless glass panel weighs roughly 45kg, and when strong winds hit it, the glass acts like a massive sail. If the foundation beneath the spigots flexes or moves by even 1 millimetre, the top of the glass panels can lean out of alignment by 20mm or more, causing the gate to jam and fail compliance.

The specific foundation and footing requirements depend entirely on the ground surface you are building on:

1. Concrete Slab Footings (The Gold Standard)

If you are building your fence onto a pool surround, a concrete slab provides the absolute best foundation.

  • Minimum Depth: The concrete slab must be a minimum of 100mm to 120mm thick.
  • Concrete Strength: It should be poured using standard structural-grade concrete (typically 25 MPa to 32 MPa strength).
  • Paver Warning: If you have decorative stone pavers or tiles, they do not count as a structural foundation. If pavers are laid on a loose bed of sand or road base, bolting a fence to them will cause them to tilt under the weight of the glass. You must ensure your core drill cuts completely through the decorative paver and bites deep into a structural concrete slab underneath.

2. Isolated Concrete Footings (For Soil, Grass, or Garden Beds)

If you are running your glass pool fence through a lawn or garden area where there is no existing concrete, you must dig and pour independent concrete piers for the spigots.

  • Dimensions: You must dig a hole at each spigot location that is at least 300mm wide by 400mm to 500mm deep (deeper if you are dealing with highly reactive clay soil).
  • The Pour: Fill these holes with wet structural concrete mixed to a minimum of 25 MPa.
  • Installation: Once cured, you can either use a diamond core drill to sink core-drilled spigots into the piers using non-shrink structural grout, or mount base-plated spigots straight into the top with heavy-duty masonry anchors.

3. Timber Deck Sub-Frame Framing

If you are installing a glass fence onto a timber or composite deck, the foundation isn’t the surface boards—it is the structural framing underneath.

  • Mandatory Under-Deck Blocking: You cannot screw glass spigots into standard 19mm decking boards. You must gain access underneath the deck and install heavy-duty timber blocking (noggings) directly between the joists right where the spigots will sit.
  • Material Size: Use structural timber blocks (such as treated pine or hardwood) that match the depth of your joists (typically 90x45mm or 140x45mm).
  • Fixings: Base-plated spigots must be bolted down using long, heavy-gauge stainless steel coach screws or structural timber screws that pass completely through the deck boards and bite deep into that solid under-deck blocking.

📊 Foundation Requirements Summary

Surface Type Minimum Structural Requirement Preferred Hardware Type
Existing Concrete / Tiles 100mm–120mm thick slab (25 MPa+ concrete) Core-drilled spigots (grouted)
Grass / Soil / Dirt 300mm wide x 400mm–500mm deep concrete piers Core-drilled or Base-plated spigots
Timber or Composite Deck Double timber blocking (noggings) under the joists Base-plated (flanged) spigots

âš¡ Don’t Forget the 1.5m Equipotential Bonding (Earthing) Law

When planning your foundations, remember Australian wiring rules (AS/NZS 3000). If any conductive metal components—such as stainless steel pool spigots, posts, or latches—are located within 1.5 metres of the pool water’s edge, they legally must be earthed (grounded) by a licensed electrician to protect swimmers from electrical faults.

If you are pouring a new concrete slab, the electrician will often need to run a copper bonding wire to the steel mesh before the concrete is poured.

Leave a Reply

Scroll to Top

Filter Categories

Categories

IMPORTANT INFORMATION FOR CHRISTMAS BREAK

Christmas 2026 Closure Dates

We wish to advise our annual Christmas holiday closure from 12pm Wednesday 23rd December, 2026. Phones and emails will not be answered during this period. We will resume normal trading hours on Monday 11th January, 2027.

Please note 2026 order cut-off dates:

  1. Local delivery booking & custom glass orders: 20th November
  2. Crate, skid & palletised orders: 27th November (please note: pre-Christmas crate delivery is not guaranteed, due to potential delays with transport companies)
  3. Postage & courier orders: 14th December
  4. Pickup from warehouse: before 2.45pm, Tuesday 22nd December.
  5. Online orders placed after 18th December may not be processed until 12th January 2027

To ensure dispatch prior to the holiday closure, orders must be received and paid/confirmed by close of business on these dates.

As at 6th November 2026, all new and current orders are subject to capacity and/or stock allocation.

Thank you for your valued business and we wish you a safe and merry Christmas.